Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.620
Filtrar
1.
Kardiologiia ; 64(3): 40-45, 2024 Mar 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38597761

RESUMO

AIM: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT). MATERIAL AND METHODS: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis. This was a blinded comparative study which assessed the AP morphometry using each of the radiation modalities without knowing the results of the method being compared. RESULTS: 100 APs were examined in the descending TA. The mean height of all analyzed APs in the descending TA was 2.2 mm [2; 2.7] for 2D TEE, 3.1 mm [2.7; 3.55] for 3D TEE, and 3.05 mm [2.55; 3.55] for MSCT. The AP heights measured with 2D TEE was statistically significantly smaller than the heights of similar APs measured either with 3D TEE or MSCT. The mean difference (bias) was 0.88±0.34 mm between 2D and 3D TEE, and 0.83±0.41 mm between 2D TEE and MSCT. The correlation coefficients for the AP heights were r=0.87 (p<0.001) between 2D and 3D TEE and r=0.86 (p<0.001) between 2D TEE and MSCT. There were no differences in the height of similar APs between 3D TEE and MSCT. CONCLUSION: The three-dimensional reconstruction of AP in the TA by TEE is more accurate for quantitative assessment of AP than a two-dimensional study.


Assuntos
Ecocardiografia Tridimensional , Placa Aterosclerótica , Masculino , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana
2.
PLoS One ; 19(4): e0302123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630708

RESUMO

BACKGROUND: Fetal two-dimensional speckle tracking echocardiography (2D-STE) is an emerging technique for assessing fetal cardiac function by measuring global longitudinal strain. Alterations in global longitudinal strain may serve as early indicator of pregnancy complications, making 2D-STE a potentially valuable tool for early detection. Early detection can facilitate timely interventions to reduce fetal and maternal morbidity and mortality. Therefore, the aim of this study was to investigate the feasibility of performing 2D-STE at 16 weeks gestational age. METHODS: This pilot study utilized 50 ultrasound clips of the fetal four-chamber view recorded between 15+5 and 16+2 weeks gestational age from a prospective cohort study. A strict protocol assessed three parameters essential for 2D-STE analysis: fetal four-chamber view ultrasound clip quality, region of interest, and frame rates. Two independent researchers measured global longitudinal strain in all adequate fetal four-chamber view ultrasound clips to determine inter- and intra-operator reliability. RESULTS: Out of the 50 ultrasound clips, 37 (74%) were feasible for 2D-STE analysis. The inter-operator reliability for global longitudinal strain measurements of the left and right ventricles was moderate (ICC of 0.64 and 0.74, respectively), while the intra-operator reliability was good (ICC of 0.76 and 0.79, respectively). CONCLUSIONS: Our findings demonstrate that fetal 2D-STE analysis at 16 weeks gestational age is feasible when adhering to a strict protocol. However, further improvements are necessary to enhance the inter- and intra-operator reliability of 2D-STE at this gestational age.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Gravidez , Feminino , Humanos , Idade Gestacional , Projetos Piloto , Reprodutibilidade dos Testes , Estudos de Viabilidade , Estudos Prospectivos , Ecocardiografia/métodos , Ventrículos do Coração , Ecocardiografia Tridimensional/métodos
3.
Echocardiography ; 41(3): e15785, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38527004

RESUMO

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cateteres , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Early Hum Dev ; 191: 105985, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38513546

RESUMO

BACKGROUND: Increased left atrial volume (LAV) is a marker of cardiovascular risk. Echocardiography standards to assess LAV in adults and children are the biplane area-length method (AL) and method of disks (MOD). LAV in neonatology is usually derived as M-mode ratio between the LA and the Aorta (LAAo). The aim of this study is to determine feasibility and reliability of these methods in neonatal clinical practice. METHODS: Clinically indicated echocardiograms in neonatal intensive care patients were retrospectively analyzed. Feasibility was determined with an image quality score describing insonation angle, foreshortening and wall clarity. Reliability was determined with Bland-Altman and correlation coefficient analysis of intra- and inter-observer measurements. RESULTS: 104 infants ranging from 23 to 39 weeks gestation were included. The feasibility of LAAo, AL and MOD was comparable (median image score 4 out of 6 points). Linear regression between AL and MOD was excellent (R2 0.99). LAAo best-fit with MOD was reached with curve-linear regression (R2 0.28) whereby a LAAo of 1.60 correlated with 1.24 ml/kg, but with a wide 95 % CI. The correlation coefficient within and between observers for LAAo, biplane AL, biplane MOD and monoplane MOD was 0.93 (0.87-0.96), 0.98 (0.96-0.99), 0.98 (0.96-0.99), 0.99 (0.97-0.99) and 0.58 (0.11-0.81), 0.75 (0.44-0.89), 0.92 (0.88-0.98), 0.96 (0.88-0.98) respectively. CONCLUSION: All methods were equally feasible and reliable when repeated by the same observer, but LAAo reliability was poor when repeated by a different observer. Biplane MOD was the most reliable and thus recommended in neonatal practice. Monoplane MOD performed well and could be considered as alternative but might be less accurate.


Assuntos
Ecocardiografia Tridimensional , Adulto , Criança , Recém-Nascido , Humanos , Ecocardiografia Tridimensional/métodos , Reprodutibilidade dos Testes , Terapia Intensiva Neonatal , Estudos Retrospectivos , Átrios do Coração/diagnóstico por imagem
5.
Echocardiography ; 41(3): e15798, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516863

RESUMO

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Fotografação
6.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501386

RESUMO

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fatores de Risco , Resultado do Tratamento , Ecocardiografia Tridimensional
7.
BMC Med Imaging ; 24(1): 61, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481130

RESUMO

OBJECTIVE: The paper aimed to improve the accuracy limitations of traditional two-dimensional ultrasound and surgical procedures in the diagnosis and management of congenital heart disease (chd), and to improve the diagnostic and therapeutic level of chd. METHOD: This article first collected patient data through real-time imaging and body surface probes, and then diagnosed 150 patients using three-dimensional echocardiography. In order to verify the effectiveness of the combination therapy, 60 confirmed patients were divided into a control group and an experimental group. The control group received conventional two-dimensional ultrasound and surgical treatment, while the experimental group received three-dimensional ultrasound and image guided surgical treatment. RESULT: In the second diagnosis, the diagnostic accuracy of type 1, type 2, and type 3 in the control group was 84.21%, 84.02%, and 83.38%, respectively. The diagnostic accuracy rates of type 1, type 2, and type 3 in the experimental group were 92.73%, 92.82%, and 92.83%, respectively. In the control group, 2 males and 1 female experienced heart failure after surgery. However, in the experimental group, 0 males and 0 females experienced heart failure after surgery. CONCLUSION: The combination of three-dimensional echocardiography and image guided surgery can improve diagnostic accuracy and surgical treatment effectiveness, thereby reducing risks and complications, and improving surgical success rate.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias Congênitas , Insuficiência Cardíaca , Cirurgia Assistida por Computador , Masculino , Humanos , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia Tridimensional/métodos , Ultrassonografia
8.
Kardiologiia ; 64(2): 73-79, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38462807

RESUMO

AIM: Vitamin D deficiency has a high prevalence in the population and is highly associated with cardiovascular diseases. The aim of this study was to evaluate subclinical left ventricular (LV) function using strain analysis in healthy individuals with vitamin D deficiency. MATERIAL AND METHODS: 113 healthy volunteers were enrolled in the study (age, 44.1±7 yrs, 34 male). All volunteers underwent two-dimensional (2D) and three-dimensional (3D) speckle tracking echocardiography after conventional echocardiographic evaluation. The subjects were divided into two groups according to their vitamin D concentrations. 61 subjects with vitamin D less than 20 ng / ml were included in the vitamin D deficiency group. The baseline clinical characteristics, laboratory measurements, echocardiographic data, including 2D and 3D global longitudinal strain (GLS) values, were compared between the groups. RESULTS: The 2D GLS values of the subjects with vitamin D deficiency were lower (mathematically less negative) than subjects with normal vitamin D (-16.1±3.4 vs -19.3±4.2, p<0.001). Similarly, the 3D GLS results were lower in subjects with vitamin D deficiency (-18.3±5.2 vs -24.1±6.9, p<0.001). A significant correlation was detected between the vitamin D concentrations and the 2D and 3D GLS measurements. (r=0.765 and r=0.628, respectively, p<0.001). Vitamin D was found to be an independent predictor of impaired 2D and 3D LV GLS (p=0.031, p=0.023, respectively). CONCLUSION: Subclinical LV dysfunction in healthy individuals with vitamin D deficiency was demonstrated by 3D and 2D strain analysis. Due to potential negative effects of vitamin D deficiency on cardiac function, more attention should be paid to healthy individuals with vitamin D deficiency.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias , Disfunção Ventricular Esquerda , Deficiência de Vitamina D , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Ecocardiografia Tridimensional/métodos , Ecocardiografia , Função Ventricular Esquerda , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/diagnóstico , Vitamina D
9.
Ultrasound Med Biol ; 50(5): 661-670, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38341361

RESUMO

OBJECTIVE: Valvular heart diseases (VHDs) pose a significant public health burden, and deciding the best treatment strategy necessitates accurate assessment of heart valve function. Transthoracic echocardiography (TTE) is the key modality to evaluate VHDs, but the lack of standardized quantitative measurements leads to subjective and time-consuming assessments. We aimed to use deep learning to automate the extraction of mitral valve (MV) leaflets and annular hinge points from echocardiograms of the MV, improving standardization and reducing workload in quantitative assessment of MV disease. METHODS: We annotated the MV leaflets and annulus points in 2931 images from 127 patients. We propose an approach for segmenting the annotated features using Attention UNet with deep supervision and weight scheduling of the attention coefficients to enforce saliency surrounding the MV. The derived segmentation masks were used to extract quantitative biomarkers for specific MV leaflet scallops throughout the heart cycle. RESULTS: Evaluation performance was summarized using a Dice score of 0.63 ± 0.14, annulus error of 3.64 ± 2.53 and leaflet angle error of 8.7 ± 8.3°. Leveraging Attention UNet with deep supervision robustness of clinically relevant metrics was improved compared with UNet, reducing standard deviations by 2.7° (angle error) and 0.73 mm (annulus error). We correctly identified cases of MV prolapse, cases of stenosis and healthy references from a clinical material using the derived biomarkers. CONCLUSION: Robust deep learning segmentation and tracking of MV morphology and motion is possible by leveraging attention gates and deep supervision, and holds promise for enhancing VHD diagnosis and treatment monitoring.


Assuntos
Aprendizado Profundo , Ecocardiografia Tridimensional , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Biomarcadores , Ecocardiografia Transesofagiana/métodos
10.
Echocardiography ; 41(2): e15776, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38353371

RESUMO

OBJECTIVE: Our goal was to use three dimensional (3D) strain analysis to evaluate myocardial function and ascending aorta elasticity changes in juvenile dermatomyositis (JDM). METHODS: Between 2019 and 2021, 23 JDM patients and 20 healthy volunteers participated. Both groups underwent 2D and 3D strain analysis, assessing aortic stiffness using aortic distensibility, stiffness index, strain, and elastic modulus. RESULTS: JDM patients had a median age of 13.3 ± 5.2 years, while controls had a median age of 13.8 ± 4.76 years. 3D strain analysis revealed significantly lower global longitudinal (GLS) and circumferential strain (GCS) in JDM patients compared to controls. Specifically, 3D GLS was notably reduced in patients (-28.1% vs. -31%, p = .047) compared to controls, and 3D GCS was also lower in patients (-27.5% vs. -30.5%, p = .019) compared to controls. Aortic strain and elastic modulus were significantly lower in JDM patients, while aortic stiffness index and distensibility showed no significant differences. Correlation analyses within the JDM group revealed a negative correlation between 3D GLS and age at diagnosis (r = -.561, p = .04), as well as a positive correlation between 3D GLS and both aortic strain (r = .514, p = .0001) and elastic modulus (r = .320, p = .03) in JDM patients. CONCLUSION: Our study demonstrated a trend towards lower ejection fraction and strain in patients with JDM, along with increased aortic stiffness using 3D echocardiography. These findings suggest potential cardiovascular involvement in juvenile dermatomyositis, emphasizing the importance of comprehensive cardiac assessments in these patients.


Assuntos
Dermatomiosite , Ecocardiografia Tridimensional , Rigidez Vascular , Humanos , Criança , Adolescente , Dermatomiosite/complicações , Dermatomiosite/diagnóstico por imagem , Coração , Ecocardiografia Tridimensional/métodos , Módulo de Elasticidade , Função Ventricular Esquerda
11.
Echocardiography ; 41(2): e15774, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38329886

RESUMO

BACKGROUND: Guidelines recommend 3D echocardiography (3DE) to assess left ventricular ejection fraction (LVEF) on transthoracic echocardiogram (TTE) when possible, but it is unclear which factors are most strongly associated with reporting 3DE LVEF in real-world practice. METHODS: We evaluated 3DE LVEF reporting by age, sex, BMI, TTE location and variation in reporting by sonographer and reader. All TTEs were performed without contrast enhancement agent at a large medical center from 9/2015 to 12/2020 using ultrasound machines capable of 3DE. We used multivariable logistic regression to assess which factors were most associated with reporting 3DE LVEF. RESULTS: Among 35 641 TTEs included in this study, 57.4% were performed on women. 3DE LVEF was reported on 18 391 TTEs (51.6% of cohort; 50.5% for women and 52.4% for men). Portable inpatient TTEs (n = 5569) had the lowest rates of 3DE LVEF reporting (30.9%), while general outpatient TTEs (n = 15 933) had greater reporting (56.9%). Outpatient TTEs with an indication for chemotherapy (n = 3244) had the highest rates of 3DE LVEF (87.2%). The median (IQR) percentage of TTEs reporting 3D LVEF was 52.7% (43.1%-68.1%) among sonographers and 51.6% (46.5%-59.6%) among readers. Among 20082 (56.3%) TTEs with 3DE LVEF measured by sonographers, 91.6% were included by readers in the final report. After adjustment, performing sonographer in the highest reporting quartile was most strongly associated with reporting 3DE LVEF (OR 7.04, 95% CI 6.55-7.56), while an inpatient portable study had the strongest negative association for reporting (OR .38, 95% CI .35-.40). CONCLUSIONS: Use of 3DE LVEF in real-world practice varies substantially based on performing sonographer and is low for hospitalized patients, but can be frequently used for chemotherapy. Initiatives are needed to increase sonographer 3DE acquisition in most clinical settings.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Masculino , Humanos , Feminino , Volume Sistólico
12.
J Vet Cardiol ; 51: 195-206, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38198977

RESUMO

Three-dimensional (3D) modeling and printing is an emerging technology in veterinary cardiovascular medicine allowing the fabrication of anatomically correct patient-specific models. These patient-specific models can be used for a wide range of purposes including medical teaching, assessment of cardiac function and movement of valve leaflets, design and assessment of devices created for interventional procedures, and pre-surgical planning [1-3]. Additionally, these 3D models can facilitate communication between the clinical team and the patient's owner. The process of creating 3D models starts with acquiring volumetric imaging data sets of the area of interest. Three-dimensional modeling and printing are reliable when high-quality volumetric imaging data are used to create these models. Currently, only ungated- and electrocardiogram (ECG)-gated computed tomography (CT), cardiac magnetic resonance imaging (CMRI), and 3D echocardiography provide the volumetric data sets needed to create these 3D models. These imaging data sets are imported into a software or open-source freeware platform and then segmented to create a virtual 3D model. This virtual 3D model can be further refined using computer-aided design (CAD) software and then be printed to create a physical 3D model. Cardiovascular 3D modeling and printing is a new medical tool which allows us to expand the way we plan interventional procedures, practice interventional skills, communicate with the medical team and owner, and teach future veterinarians.


Assuntos
Angiografia por Tomografia Computadorizada , Ecocardiografia Tridimensional , Animais , Angiografia por Tomografia Computadorizada/veterinária , Impressão Tridimensional , Tomografia Computadorizada por Raios X/veterinária , Coração/diagnóstico por imagem
13.
J Am Soc Echocardiogr ; 37(4): 408-419, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38244817

RESUMO

BACKGROUND: The assessment of ventricular secondary mitral regurgitation (v-SMR) severity through effective regurgitant orifice area (EROA) and regurgitant volume (RegVol) calculations using the proximal isovelocity surface area (PISA) method and the two-dimensional echocardiography volumetric method (2DEVM) is prone to underestimation. Accordingly, we sought to investigate the accuracy of the three-dimensional echocardiography volumetric method (3DEVM) and its association with outcomes in v-SMR patients. METHODS: We included 229 patients (70 ± 13 years, 74% men) with v-SMR. We compared EROA and RegVol calculated by the 3DEVM, 2DEVM, and PISA methods. The end point was a composite of heart failure hospitalization and death for any cause. RESULTS: After a mean follow-up of 20 ±11 months, 98 patients (43%) reached the end point. Regurgitant volume and EROA calculated by 3DEVM were larger than those calculated by 2DEVM and PISA. Using receiver operating characteristic curve analysis, both EROA (area under the curve, 0.75; 95% CI, 0.68-0.81; P = .008) and RegVol (AUC, 0.75; 95% CI, 0.68-0.82; P = .02) measured by 3DEVM showed the highest association with the outcome at 2 years compared to PISA and 2DEVM (P < .05 for all). Kaplan-Meier analysis demonstrated a significantly higher rate of events in patients with EROA ≥ 0.3 cm2 (cumulative survival at 2 years: 28% ± 7% vs 32% ± 10% vs 30% ± 11%) and RegVol ≥ 45 mL (cumulative survival at 2 years: 21% ± 7% vs 24% ± 13% vs 22% ± 10%) by 3DEVM compared to those by PISA and 2DEVM, respectively. In Cox multivariable analysis, 3DEVM EROA remained independently associated with the end point (hazard ratio, 1.02, 95% CI, 1.00-1.05; P = .02). The model including EROA by 3DEVM provided significant incremental value to predict the combined end point compared to those using 2DEVM (net reclassification index = 0.51, P = .003; integrated discrimination index = 0.04, P = .014) and PISA (net reclassification index = 0.80, P < .001; integrated discrimination index = 0.06, P < .001). CONCLUSIONS: Effective regurgitant orifice area and RegVol calculated by 3DEVM were independently associated with the end point, improving the risk stratification of patients with v-SMR compared to the 2DEVM and PISA methods.


Assuntos
Ecocardiografia Tridimensional , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Masculino , Humanos , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Curva ROC , Índice de Gravidade de Doença
14.
Lupus ; 33(2): 155-165, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38182135

RESUMO

BACKGROUND: Systemic lupus erythematosus (SLE) is a complex autoimmune connective tissue disease (CTD) that is an important cause of devastating pulmonary arterial hypertension (PAH), and persistent progression of PAH can lead to right heart failure, predicting a poor prognosis for SLE patients. Right ventricular-pulmonary arterial (RV-PA) coupling with echocardiography has been demonstrated to be a noninvasive alternative method for evaluating PAH patients' predictive outcomes. Whether the ratio of right ventricular stroke volume (RVSV) to right ventricular end-systolic volume (RVESV) measured by three-dimensional echocardiography (3DE) is a new index of RV-PA coupling has not been discussed as a new predictor for the clinical outcome of systemic lupus erythematosus-associated pulmonary arterial hypertension (SLE-PAH). METHODS: From June 2019 to February 2023, 46 consecutive patients with SLE-PAH were enrolled prospectively, and their clinical data and echocardiographs were studied and analyzed. The control group consisted of 30 healthy subjects matched for age, sex, and body surface area (BSA). The main endpoints of this study were a composite of all-cause mortality and adverse clinical events. Baseline clinical characteristics and echocardiographic assessments were analyzed. RESULTS: During a median of 24 months (IQR 18-31), 16 of 46 SLE-PAH patients (34.7%) experienced endpoint-related events. At baseline, patients who experienced mortality or adverse events had a worse WHO functional class (WHO FC) and lower anti-double-stranded DNA (dsDNA) antibody levels. The right ventricular (RV) systolic dysfunction in SLE-PAH subjects was significantly worse than that in the healthy control group, especially in SLE-PAH patients in the endpoint event group. Compared to controls, patients with SLE-PAH had a lower RVSV/RVESV ratio. In the group comparison, patients who had experienced an endpoint event had a sequentially worse ratio (1.86 (1.65-2.3) versus 1.30 (1.09-1.46) versus 0.64 (0.59-0.67), p < .001). There were statistically significant associations between the RVSV/RVESV ratio to routine RV systolic function and clinical parameters. The RVSV/RVESV ratio was negatively correlated with the WHO FC (r = -0.621, p < .001) and positively correlated with the anti-dsDNA level. The ROC curve showed that the optimal cutoff for RVSV/RVESV < 0.712 determined a higher risk of poor prognosis. Kaplan‒Meier survival curves showed that an RVSV/RVESV ratio >0.712 was associated with more favorable long-term outcomes. CONCLUSIONS: The 3DE-derived SV/ESV ratio as a noninvasive alternative surrogate of RV-PA coupling was an eximious indicator for identifying endpoint events in SLE-PAH patients and can provide a diagnostic basis for clinical intervention.


Assuntos
Ecocardiografia Tridimensional , Hipertensão Pulmonar , Lúpus Eritematoso Sistêmico , Hipertensão Arterial Pulmonar , Disfunção Ventricular Direita , Humanos , Hipertensão Pulmonar/etiologia , Lúpus Eritematoso Sistêmico/complicações , Ecocardiografia Tridimensional/métodos , Ecocardiografia , Disfunção Ventricular Direita/etiologia
15.
Ann Noninvasive Electrocardiol ; 29(1): e13104, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288512

RESUMO

OBJECTIVE: This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT-3D-TEE in MVP. METHODS: A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software. RESULTS: The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral-to-posteromedial diameter (DAlPm ), anterior-to-posterior diameter (DAP ), annulus height (HA ), three-dimensional annulus circumference (CA3D ), two-dimensional annulus area (AA2D ), anterior leaflet area (Aant ), posterior leaflet area (Apost ), anterior leaflet length (Lant ), posterior leaflet length (Lpost ), and tenting volume (Vtent ) compared to the control group. CONCLUSION: Real-time three-dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision-making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.


Assuntos
Valvuloplastia com Balão , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral , Humanos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Eletrocardiografia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
16.
Echocardiography ; 41(1): e15761, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284686

RESUMO

BACKGROUND: Aorto-left ventricular tunnel (ALVT) is a paravalvular communication between aorta and left ventricle. It is one of the rare congenital heart diseases which could present with heart failure. CASE PRESENTATION: A case of ALVT was diagnosed in infancy. Preliminary assessment was possible using conventional echocardiography; however, functional assessment and accurate anatomy of ALVT were further verified via variable imaging modalities starting from speckle tracking and three-dimensional echocardiography to cardiac CT angiogram. The tunnel was successfully repaired with uneventful recovery. CONCLUSIONS: Multimodality imaging can accurately assess cardiac function and demonstrate the anatomy of ALVT noninvasively to plan for successful intervention.


Assuntos
Túnel Aorticoventricular , Ecocardiografia Tridimensional , Cardiopatias Congênitas , Humanos , Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aorta/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Ventrículos do Coração/anormalidades
17.
BMC Cardiovasc Disord ; 24(1): 51, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38221637

RESUMO

Mitral valve aneurysm (MVA) is characterized by a saccular outpouching of the mitral leaflet, and it represents a rare condition typically associated with aortic valve endocarditis. Three-Dimensional Transesophageal Echocardiography (3D-TEE) serves as an effective tool for detecting the presence of MVA and its potential complications. In this report, we present a case involving a young man with striking images of bicuspid aortic valve endocarditis complicated by an aortic root abscess and multiple perforated mitral valve aneurysms, diagnosed using 3D TEE. This case suggests the uncommon coexistence of Marfan like morphotype, bicuspid aortic valve, and infective endocarditis as a triple mechanism in the occurrence of MVA. It underscores the significance of early and accurate imaging diagnosis for facilitating prompt surgical intervention.


Assuntos
Doença da Válvula Aórtica Bicúspide , Ecocardiografia Tridimensional , Endocardite Bacteriana , Endocardite , Aneurisma Cardíaco , Síndrome de Marfan , Humanos , Masculino , Abscesso/diagnóstico por imagem , Abscesso/etiologia , Aorta Torácica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Ecocardiografia Transesofagiana/métodos , Endocardite/complicações , Endocardite/diagnóstico por imagem , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/complicações , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia
18.
Clin Res Cardiol ; 113(3): 367-392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37079054

RESUMO

INTRODUCTION: Real-time three-dimensional echocardiography (RT3DE) is currently being developed to overcome the challenges of two-dimensional echocardiography, as it is a much cheaper alternative to the gold standard imaging method, cardiac magnetic resonance (CMR). The aim of this meta-analysis is to validate RT3DE by comparing it to CMR, to ascertain whether it is a practical imaging method for routine clinical use. METHODS: A systematic review and meta-analysis method was used to synthesise the evidence and studies published between 2000 and 2021 were searched using a PRISMA approach. Study outcomes included left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), left ventricular ejection fraction (LVEF), left ventricular mass (LVM), right ventricular end-systolic volume (RVESV), right ventricular end-diastolic volume (RVEDV) and right ventricular ejection fraction (RVEF). Subgroup analysis included study quality (high, moderate), disease outcomes (disease, healthy and disease), age group (50 years old and under, over 50 years), imaging plane (biplane, multiplane) and publication year (2010 and earlier, after 2010) to determine whether they explained the heterogeneity and significant difference results generated on RT3DE compared to CMR. RESULTS: The pooled mean differences for were - 5.064 (95% CI - 10.132, 0.004, p > 0.05), 4.654 (95% CI - 4.947, 14.255, p > 0.05), - 0.783 (95% CI - 5.630, 4.065, p > 0.05, - 0.200 (95% CI - 1.215, 0.815, p > 0.05) for LVEF, LVM, RVESV and RVEF, respectively. We found no significant difference between RT3DE and CMR for these variables. Although, there was a significant difference between RT3DE and CMR for LVESV, LVEDV and RVEDV where RT3DE reports a lower value. Subgroup analysis indicated a significant difference between RT3DE and CMR for studies with participants with an average age of over 50 years but no significant difference for those under 50. In addition, a significant difference between RT3DE and CMR was found in studies using only participants with cardiovascular diseases but not in those using a combination of diseased and healthy participants. Furthermore, for the variables LVESV and LVEDV, the multiplane method shows no significant difference between RT3DE and CMR, as opposed to the biplane showing a significant difference. This potentially indicates that increased age, the presence of cardiovascular disease and the biplane analysis method decrease its concordance with CMR. CONCLUSION: This meta-analysis indicates promising results for the use of RT3DE, with limited difference to CMR. Although in some cases, RT3DE appears to underestimate volume, ejection fraction and mass when compared to CMR. Further research is required in terms of imaging method and technology to validate RT3DE for routine clinical use.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Direita , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração , Espectroscopia de Ressonância Magnética
19.
Pediatr Cardiol ; 45(3): 660-665, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37020140

RESUMO

Mitral valve cleft (MVC) is the most common cause of congenital mitral regurgitation (MR). MVC may be located on the anterior or posterior leaflets. We evaluated children with moderate-to-severe MR using 3D transthoracic echocardiography (3DTTE) to diagnose MVC and determine the location, shape and size of MVC. Twenty-one patients under 18 years of age with moderate-to-severe MR without symptoms who were suspected of having MVC were included in the study. The patients' history and clinical data were obtained from the medical records. 2D and 3D imaging were performed with a high-quality machine (EPIQ CVx). A vena contracta (VC) of colour Doppler regurgitated jet 3-7 and ≥ 7 mm defined moderate-to-severe regurgitation. An isolated anterior leaflet cleft (ALC) was detected in four patients, an isolated posterior leaflet cleft (PLC) in 12 patients, and both an ALC and PLC in five patients. VC was larger in patients with ALCs than PLCs (8.85 mm vs. 6.64 mm). Global LV longitudinal strain was better in the ALC group than in the PLC and both-posterior-and anterior MVC groups (- 24.7, - 24.3, and - 24%, respectively). Global circumferential strain was better in the ALC group (- 28.9%) and reduced in the bi-leaflet MVC group (- 28.6%). 3DTTE for visualisation of the MV can be successfully implemented in children and should be proposed during follow-up. AMVC and bi-leaflet MVC results in severe regurgitation and bi-leaflet MVC may be the reason for systolic dysfunction determined before clinically proven symptoms in the future.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Criança , Humanos , Adolescente , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Ultrassonografia Doppler em Cores
20.
Catheter Cardiovasc Interv ; 103(1): 243-247, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37855193

RESUMO

A mitral paravalvular leak (PVL) is a significant complication of surgical valve replacement that has a profound impact on the health and survival of patients. Transcatheter closure of PVL has emerged as a promising treatment option. We present the case of a 65-year-old patient who experienced exertional dyspnea, chest tightness, and peripheral edema (New York Heart Association functional class Ⅵ) following surgical aortic and mitral valve replacement. Echocardiography and computed tomography performed on admission revealed a giant mitral PVL (1 bundle, volume 25.0 mL, area 13.0 cm²). Due to the patient's high surgical risk and complex anatomical characteristics, a patient-specific three-dimensional printed model was utilized to visualize anatomical structures and simulate the main procedures. After careful consideration, the surgical team opted to perform transcatheter closure of the giant mitral PVL via a transapical concomitant transseptal approach using two carefully selected devices of different sizes (14-mm and 16-mm Amplatzer Vascular Plug II). The procedure was carried out successfully. During the 1-month follow-up, the patient remained asymptomatic (New York Heart Association functional class Ⅰ). Transcatheter closure of a giant and complex mitral PVL utilizing three-dimensional printing guidance has proven to be a feasible approach.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Idoso , Falha de Prótese , Resultado do Tratamento , Cateterismo Cardíaco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...